Belden RG59 - 9105SL2P - 20 AWG - Coaxial Cable + Power
Update Terakhir
24/08/2024 13.59.53
Minimum Pembelian
1
Roll
Harga
Call
Deskripsi Produk
PT. VISINDO GLOBAL TEKNOLOGI adalah MASTER DEALER untuk Produk Belden seperti Kabel RG59 - 9105SL2P - 20 AWG - Coaxial Cable + Power dengan spesifikasi sbb :
Detailed Specifications &
Technical Data
9105SL2P Coax – Series 59
RG59 Coaxial
20 AWG Solid Conductor
Cable Length 305 Meter
Impendance : 75 Ohm
Description:
Series 59, 20 AWG 0.81mm solid bare copper covered steel conductor, gas-injected foam polyethylene insulation, aluminum-PET
tape + aluminum braid shield (59% coverage), PVC jacket, with two power conductors.
PHYSICAL CHARACTERISTICS:
COAX CONDUCTOR:
Number of Coax 1
Total Number of Conductor 1
Series Type Series 59
AWG 20
Stranding Solid
Conductor Nominal Diameter 0.81 mm
Conductor Material BCCS - Bare Copper Covered Steel
INSULATION:
Insulation Material Gas-injected FPE - Foam Polyethylene
Insulation Nominal Diameter 3.66 mm
OUTER SHIELD:
Outer Shield Type Tape / Braid
Outer Shield Material:
Layer Number Type Material Nom. Coverage (%)
1 Tape Bonded Aluminum Foil – Polyester Tape 100
2 Braid AL – Aluminum 59
POWER CABLE:
Conductor stranded Construction 7/0.37 mm
Conductor Material Copper Clad Aluminum
Insulation Material Polyethylene
Insulation Color Red & Black
OVERALL OUTER JACKET:
Detailed Specifications &
Technical Data
9105SL2P Coax – Series 59
Page 2 of 3
Outer Jacket Material PVC - Polyvinyl Chloride
OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter 6.0 x 4.5 x 10.8 mm
MECHNICAL CHARACTERISTICS:
Operating Temperature Range (Non-UL) - 20℃ To + 75℃
Bulk Cable Weight 56 kg/km
Max. Recommended Pulling Tension 630 N
Min. Bend Radius (Install) 60 mm
APPLICABLE SPECIFICATION AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
EU CE Mark (Y/N) N
EU RoHS Compliant (Y/N) Y
EU RoHS Compliance Date Dec 2007
FLAME TEST:
Flame Test VW-1
SUITABILITY:
Suitability-Indoor Yes
Suitability-Outdoor Yes
Sunlight Resistance Yes
SWEEP TEST:
Sweep Testing 5 MHz – 1 GHz
ELECTRICAL CHARACTERISTICS:
Nom. Characteristics Impedance 75 +/- 3 Ohms
Nom. Velocity of Propagation 82 %
Nom. Conductor DC Resistance @ 20 Deg.C 161.4 Ohms/km (Coax cable)
Max. Conductor DC Resistance @ 20 Deg.C 40 Ohms/km (Individual Power core)
Nom. DC Loop Resistance @ 20 Deg.C 172 Ohms/km
Min. Structural Return Loss (5~1000 MHz) 20 dB
Max. Attenuation @ 20 Deg.C:
Frequency
(MHz)
Max. Attenuation
(dB/100m)
Frequency
(MHz)
Max. Attenuation
(dB/100m)
5 2.82 400 16.01
55 6.17 450 17.39
211 11.78 550 19.36
270 13.29 750 22.83
Detailed Specifications &
Technical Data
9105SL2P Coax – Series 59
Page 3 of 3
PUT-UPS AND COLORS:
Item Description Put-Up* (metre) Ship Weight (kg) Jacket Color
9105SL2P 010A305M #20 GIFHDLDPE SH PVC WPM 305M 17 BLACK
9105SL2P 009A305M #20 GIFHDLDPE SH PVC WPM 305M 17 WHITE
* Other lengths available upon request.
Revision Number: 2 Revision Date: 28/4/2017.
Untuk mendapatkan harga terbaik , di mohon untuk menghubungi sales kami.
HARGA NEGO.............................................................
VINSEN / LASMI
PT. VISINDO GLOBAL TEKNOLOGI
Mangga Dua Square Lt. 2 Blok B No. 010 - 012
Jl. Gunung Sahari Raya No. 1 Jakarta Utara
Detailed Specifications &
Technical Data
9105SL2P Coax – Series 59
RG59 Coaxial
20 AWG Solid Conductor
Cable Length 305 Meter
Impendance : 75 Ohm
Description:
Series 59, 20 AWG 0.81mm solid bare copper covered steel conductor, gas-injected foam polyethylene insulation, aluminum-PET
tape + aluminum braid shield (59% coverage), PVC jacket, with two power conductors.
PHYSICAL CHARACTERISTICS:
COAX CONDUCTOR:
Number of Coax 1
Total Number of Conductor 1
Series Type Series 59
AWG 20
Stranding Solid
Conductor Nominal Diameter 0.81 mm
Conductor Material BCCS - Bare Copper Covered Steel
INSULATION:
Insulation Material Gas-injected FPE - Foam Polyethylene
Insulation Nominal Diameter 3.66 mm
OUTER SHIELD:
Outer Shield Type Tape / Braid
Outer Shield Material:
Layer Number Type Material Nom. Coverage (%)
1 Tape Bonded Aluminum Foil – Polyester Tape 100
2 Braid AL – Aluminum 59
POWER CABLE:
Conductor stranded Construction 7/0.37 mm
Conductor Material Copper Clad Aluminum
Insulation Material Polyethylene
Insulation Color Red & Black
OVERALL OUTER JACKET:
Detailed Specifications &
Technical Data
9105SL2P Coax – Series 59
Page 2 of 3
Outer Jacket Material PVC - Polyvinyl Chloride
OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter 6.0 x 4.5 x 10.8 mm
MECHNICAL CHARACTERISTICS:
Operating Temperature Range (Non-UL) - 20℃ To + 75℃
Bulk Cable Weight 56 kg/km
Max. Recommended Pulling Tension 630 N
Min. Bend Radius (Install) 60 mm
APPLICABLE SPECIFICATION AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
EU CE Mark (Y/N) N
EU RoHS Compliant (Y/N) Y
EU RoHS Compliance Date Dec 2007
FLAME TEST:
Flame Test VW-1
SUITABILITY:
Suitability-Indoor Yes
Suitability-Outdoor Yes
Sunlight Resistance Yes
SWEEP TEST:
Sweep Testing 5 MHz – 1 GHz
ELECTRICAL CHARACTERISTICS:
Nom. Characteristics Impedance 75 +/- 3 Ohms
Nom. Velocity of Propagation 82 %
Nom. Conductor DC Resistance @ 20 Deg.C 161.4 Ohms/km (Coax cable)
Max. Conductor DC Resistance @ 20 Deg.C 40 Ohms/km (Individual Power core)
Nom. DC Loop Resistance @ 20 Deg.C 172 Ohms/km
Min. Structural Return Loss (5~1000 MHz) 20 dB
Max. Attenuation @ 20 Deg.C:
Frequency
(MHz)
Max. Attenuation
(dB/100m)
Frequency
(MHz)
Max. Attenuation
(dB/100m)
5 2.82 400 16.01
55 6.17 450 17.39
211 11.78 550 19.36
270 13.29 750 22.83
Detailed Specifications &
Technical Data
9105SL2P Coax – Series 59
Page 3 of 3
PUT-UPS AND COLORS:
Item Description Put-Up* (metre) Ship Weight (kg) Jacket Color
9105SL2P 010A305M #20 GIFHDLDPE SH PVC WPM 305M 17 BLACK
9105SL2P 009A305M #20 GIFHDLDPE SH PVC WPM 305M 17 WHITE
* Other lengths available upon request.
Revision Number: 2 Revision Date: 28/4/2017.